COMPARATIVE STUDYBETWEEN T ROPONIN T AND OTHER CARDIAC AMRICERS ( T ROPONIN I AND CK MB) IN END STAGE HEMODIALYSIS PAT EINT S
Files
Date
2007
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Neelain University
Abstract
Abstract
The present study aims is to assessment the diagnostic value of cardiac
troponin T (cTnT) as a new cardiac marker in patients with chronic renal
failure undergoing long term haemodialysis in Sudan using Roche diagnostic
ELECSYS 2010 immunoassay compare with other cardiac marker troponin I
and CK MB using immulite automated immunoassay and spectrophotometer
respectively .
Study group of 75 Sudanese patients ( 53 male and 22 female) . patients had
and age range (38-80) ( mean age is 59 years ) and 25 healthy subjects was
enrolled a control group , blood sample was taken from all patients before
starting dialysis .
According to assessment of troponin T concentration the study indicate that
elevation level of troponin T ( a cutoff cTnT ) >0.l ng /ml are detectable in
28%(n=21) of patients , troponin I cut off (cTnT) 1.0 ngml )detectable in 12
% (n=9) were CK MB (cut off 24.0 u/I) are detectable in 6.7 % (n=5 ) .
Diabetics resemble (43%) of patients which have positive troponin T .
determination of CtnI and CK MB level can be helpful but these marker
hade serious analytical and clinical limitation .
This study confirm the troponin T demonstrate improved sensitivity and
specifity when compared to the other biochemical marker among
haemodialysis patients .
The study confirm that the troponin T is an important diagnostic marker that
can be used for early detection of myocardial infarction (MI ) among
haemodialysis and follow up of patients particularly when such infonnation
can not be obtain .
Description
Thesis submitted in'"fulfillment for requirement of
MSc. in medical laboratory techniques
Keywords
T ROPONIN