Estimation of Effective Dose During Common Computed Tomography Examinations in Khartoum State
Date
2018
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Neelain University
Abstract
Abstract
The aim of this study was to estimate the effective dose received by patient underwent different computed tomography examinations in Khartoum state. The Data were collected from 141 patients for brain, abdomen and pelvis at three hospitals in the period from March to May 2018. Patient dose was estimated from volume, computed tomography dose index, dose length product, and exposure related parameter and coefficients factor K from European guideline. Variations of mean effective dose between hospitals were observed for similar computed tomography examination. These variation due to different computed tomography scanning in different hospital and scanner type .The result of mean computed tomography dose index, dose length product Were (38.32±562.8), (71.75±1368.15), (78.35±1202.38) (mGy± mGy/cm) for brain of Asia, Military and Bugaa respectively; while estimated effective dose stand at 1.181 mGy for Asia brain result and 2.873 mGy for military which were higher than effective dose result in bugga which was 2.525 mGy . The mean of computed tomography dose index and dose length product for abdomen results showed (12.30±993.45), (51.75±2416.06), (8.25±161.263)(mGy,mGy/cm) for abdomen of asia , military and bugaa respectively. The results of the effective dose was found to be 14.903 mGy for Asia and much higher in military about 36.238mGy and even much higher at bugaa about 161.263 mGy for abdomen .the results of volume computed tomography dose index and dose length product of Pelvis were (10.70±272.60), (33.50±1100.00), (18.56±2309.94) (mGy,mGy/cm) for asia, military and bugaa respectively and the effective dose were 4.088 mGy of asia and large variation orientated in military result which were16.499 mGy. It has been clarified that effective dose of bugaa are much far than mentioned results about 34.648 mGy. Finally the results of this study were compared with some studies in Sudan and other countries. It shows that there were large variations between the resulted values of anther studies comes due to different protocol imaging in the same and differ centers, patient weight, and size. This study recommended developing a standard protocol for each computed tomography examination to be applied in all hospitals in Sudan.
الخـــلاصـــــــــــــــه
الهدف من الدراسه هو تقدير الجرعه الفعاله التي يتلقاها المريض خلال فحوصات الاشعه المقطعيه المختلفه بولايه الخرطوم . جمعت البيانات من 141 مريض للمخ – البطن – الحوض من ثلاث مستشفيات في الفتره من مارس وحتي مايو2018. تم تقييم جرعه المريض باستخدام و وباستخدام عوامل التعرض والعامل K من المبادئ الاوربيه. لوحظ اختلاف في متوسط الجرعه الفعاله بين المستشفيات الثلاثه لنفس الفحص. هذا الفرق نتيجه الاختلاف الفحص ونوع جهاز الاشعه المقطعيه المستخدم. كان متوسط جرعات للمخ (38.32±562.8), (71.75±1368.15), (78.35±1202.38) (mGy± mGy\cm) لمستشفي اسيا والسلاح الطبي والبقعه علي التوالي بينما متوسط الجرعه الفعاله ابتداء من 1.81mGy لفحص المخ في مستشفي اسيا و2.873mGy لمستشفي السلاح الطبي وهي اعلي قيمه للجرعه الفعاله مقارنه مع نتيجه البقعه وهي2.525mGy. بالرغم من ان متوسط الجرعه الفعاله لل لمنطقه البطن كانت(12.30±993.45), (51.75±2416.06), (8.25±161.263) (mGy, mGy\cm) لكل من مستشفي اسيا والسلاح الطبي والبقعه علي التوالي وجد ان الجرعه الفعاله كانت 14.903mGy لاسيا واعلي قيمه للجرعه الفعاله كانت في السلاح الطبي هي 36.238mGy بينما الاعلي علي الاطلاق كانت 161.263mGy لفحص البطن في مستشفي البقعه.ايضا كانت متوسط جرعات ال لمنطقه الحوض (10.70±272.60), (33.50±1100.00), (18.56±2309.94) (mGy, mGy\cm) لكل من مستشفي اسيا والسلاح والبقعه علي التوالي بينما الجرعه الفعاله لاسيا كانت 4.088mGy ووجد اختلاف كبير في نتيجه السلاح لمنطقه الحوض وهي 16.499mGyكما كانت نتيجه فحص الحوض للبقعه مختلفه عن ما ذكر من نتائج منطقه الحوض وهي 34.648mGy. كما قورنت النتائج في هذه الدراسه مع دراسات سابقه في السودان ودول احري والتي وضح من خلالها وجود اختلاف بينهما ويعزي الاختلاف الي انواع الاجهزه المقطعيه الموجوده بالمستشفيات واختلاف معاملات التصوير وطرقه والي اختلاف حجم و وزن المريض.
Description
Keywords
Tomography Examinations