Homebuilt Flash Photolysis Setup to Study Optical and Electrical Properties of Whole Blood
Date
2021
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Al-Neelain University
Abstract
Abstract
In this study a flash photolysis setup was built by available apparatus in Alneelain University, and
used time resolved optical spectroscopy method to give absorbance spectrum of normal human
blood sample and comparison to reference data in Previous Studies, and then drawing energy level
diagram of this sample, and calculated some physical properties, and study the effect of time
exposure on human blood sample by Laser Flash Photolysis. Nanosecond transient absorption
experiments were performed using a laser flash photolysis (LFP) homebuilt with a Q-switched
Nitrogen laser with a 337 nm output wavelength, 10 ns pulse width, 1 Hz repetition rate, and 40
mJ pulse energy. The optical detection is based on a pulsed Xenon arc lamp (75 W), spectra were
recorded by Ocean Optics spectrometer and used origin 9 software to analysis data. Blood sample
were put on a quartz cell 1x1 cm mounted on a homebuilt sample holder that is placed at the cross-
section of the laser incident beam and the probe flash lamp.
The experiment carried out the absorbance spectrum and drawing the energy level diagram of
blood sample in three excited states, first excited state Start absorption band at 591 nm and end
absorption band at 558 nm, second excited state Start absorption band at 562 nm and end
absorption band at 517 nm and the last excited state Start absorption band at 463 nm and end
absorption band at 390 nm.
Diffuse scatter laser flash photolysis has been used in blood sample to calculated transient triplet
spectra of free radical or reactive oxygen species (OH, O 2 , H 2 O 2 ) generated in free cell systems
was investigated using laser flash photolysis and electronic absorption spectra. In all cases, triplet–
triplet absorption spectra with the application of this technique to studies concentration of normal
human blood sample. Laser photolysis at three region (415 nm, 541 nm and 573 nm) .The
concentration of normal human blood sample is related to the absorbance as Beer’s law reduces
the concentration of normal human blood sample. The concentration at the first region 415 nm
decreases by rated 0.13212 and on the second region at 541 nm by rated 0.01814 and at last for
the 573 nm decreases by rated 0.01794 for the quantum yield was obtained. Absorbance verses
wavelength measurements can thus be converted into concentration verses time from which the rate of reaction was calculated
المستخلص
في هذه الدراسة تم بناء منظومة ( LFP)(Laser flash photolysis) من الأجهزة المتاحة في جامعة أليلين، تم استخدام معادلات تحليل الزمن لأطياف الأمتصاص لعينة من الدم الطبيعي لحساب منحني الإمتصاص وتمت مقارنته النتيجة مع المعلومات المرجعية في الدراسات السابقة، ثم رسم مخطط مستوى الطاقة لهذه العينة . ومن ثم تم دراسة بعض الخصائص الضوئية ودرس أثر الزمن علي هذه العينة .
تجربة الإمتصاص النانوي لتوهج الضوء العادي والليزر بواسطة منظومة (LFP) المصنعة في جامعة النيلين أستخدم فيها ليزر النيتروجين ذى الطول الموجي 337 نانوميتر ذو النمط النبضي 10 نانوثانية و الطاقة 40 ملي جول وتردد واحد هرتز . واستخدم مصباح نبضي بطاقة 75 واط ، أستخدم مطياف USB 2000 ككاشف ضوئي لتسجيل النتائج . وأستخدم برنامج (origin 9 ) لمعالجة البيانات . وضعت عينة الدم الطبيعي في أنبوب من الكوارتز سنتمترx سنتمتر وضعت علي حامل في المنظومة المصصمة عند تقاطع ضوء الليزر وضوء اللمبة .
أعطت التجربة طيف أمتصاص و من ثم تم رسم مستويات طاقة في ثلاثة مناطق من الطيف كالأتي ,المستوي الأول يبدأ من 591 نانومتر، حتي 558 نانومتر والمستوي الثاني يبدأ من 562 نانومتر و حتي 517 نانومتر والمستوي الأخير يبدأ من من 463 نانومتر و حتي 390 نانومتر .
Description
A Thesis Submitted for the fulfillment of the requirements for the degree
of Doctor of philosophy in Laser physics
Keywords
philosophy, Laser physics