Measurements of RF/MW Radiation Emitted from Selected Mobile-Phone Base-Stations in Sudan
dc.contributor.author | S.T. Kafi, A.M.Ahmed | |
dc.contributor.author | Ibrahim.E.A | |
dc.date.accessioned | 2018-01-18T12:25:49Z | |
dc.date.available | 2018-01-18T12:25:49Z | |
dc.date.issued | 2008-10 | |
dc.description.abstract | Scattering of mobile-phone base-stations within populated areas is a source of some misscomfortableness to many people. As there is no one agreed on safety level for the MPE for RF/MW allover the world, measurements of radiation emitted from base-stations is a necessity. In this work we screened out some mobile-phone base-stations inside and outside Khartoum city in Sudan. Measurements were done indoor and outdoor to maximum horizontal distance of about 300 m from the base of the base-stations. Results obtained were then compared to the maximum and minimum MPE values admitted in different countries in the world. The maximum MPE value (i.e- 0.57 mW/cm2) consider only the thermal effects of the RF/MW, while other values tend to reduce the exposure limits to as minimum as possible for safety considerations (considering non-thermal effects). Some of the values obtained were consistent with some reported biological effects. We recommended the removal of some base-stations from sensitive areas like schools, kindergardens, hostels, hospitals, etc. | en_US |
dc.identifier.uri | http://hdl.handle.net/123456789/10380 | |
dc.language.iso | en | en_US |
dc.subject | Radiofrequency and microwaves | en_US |
dc.subject | base-stations | en_US |
dc.subject | MPE | en_US |
dc.title | Measurements of RF/MW Radiation Emitted from Selected Mobile-Phone Base-Stations in Sudan | en_US |
dc.type | Article | en_US |