Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Mustafa Eltigani Mustafa Yassin"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    Item
    Establishment and evaluation of RT-LAMP for HIV-1 P24 gene detection in comparison with RT-PCR, and COBAS TaqMan real time RT-PCR among Sudanese
    (Alneelain University, 2014-12) Mustafa Eltigani Mustafa Yassin
    Abstract Background: A rapid, simple, cost efficient, nucleic acid based test for detecting HIV-1 in resource poor or field settings is highly desirable. Recent molecular techniques based on genomic sequence detection such as RT- PCR, real-time PCR are sensitive and rapid, but these methods use thermocycling equipment and so are impractical for field applications and for use in less developed laboratories. Loop-mediated isothermal amplification (LAMP) is a new developed technique which can amplify nucleic acids DNA and RNA (LA1\/IP and RT-LAMP, respectively) with high specificity, sensitivity and rapidity under isothermal conditions. Objective: The objective of this study is establishment and evaluation of RT- LAIVIP, for HIV-1 P24 gene in comparison with RT-PCR, and COBAS TaqMan real time RT-PCR. Materials and Methods: Ninety EDTA anticoagulated blood samples were collected, 70 from HIV -1 positive participants (ELISA, and western blot), and the remaining 20 samples were collected from HIV-1 negative participants (ELISA), all samples were tested for HIV-1 P24 gene with RT-LAIVIP and RT-PCR, nine HIV-1 positive sample viral load were detected using COBAS® TaqMan® HIV-1 Test, version 2.0 (v2.0) for use with the high pure system. Results: All samples were tested for HIV-1 P24 gene using RT-LAl\/[P and RT- PCR, 68/70 were positive with RT-LAl\/[P (97.1%), and 61/70 were positive with RT-PCR (87.1%). All 20 HIV-1 negative sample were negative with RT-LAMP 20/20 (100%) and 18 were negative with RT-PCR 18/20 (90 The detection limit of RT-LAl\/[P assay were detected by diluting RNA with 6.69 X105 HIV-1 copies/ml, and 1.3 X104 copies/ml, the reproducible 100% detection limit of the RT-LAMP assay was 130 and 162 copies/ml, compared to 522 and 325 copies/ml with RT-PCR. Conclusion: I RT-LAMP is an inexpensive, rapid assay and valuable tool for the detection of HIV-1 RNA in plasma. The RT-LA1\/IP was performed under isothermal conditions at 63 °C and no sophisticated equipments were needed, which make it more reliable for use in developing countries, like Sudan.

DSpace software copyright © 2002-2025 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify