Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Ahmed Bolad, Elham O Mahgoub"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    Item
    Correctness and accuracy of template-based modeled single chain fragment variable (scFv) protein anti-breast cancer cell line (MCF-7)
    (Scientific Research Publishing, 2013-08-01) Ahmed Bolad, Elham O Mahgoub
    Multiple sequence alignments can be used in the tem- plate-based modelling of protein structures to build fragment-based assembly models. Therefore, useful functional information on the 3D structure of the anti-MCF-7 scFv protein can be obtained using available bioinformatics tools. This paper utilises several commonly-used bioinformatics tools and da- tabases, including BLAST (Basic Local Alignment Search Tool), GenBank, PDB (Protein Data Bank), KABAT numbering and SWISS-MODEL, to gain specific functional insights into the anti-MCF-7 scFv protein and the assembly of single-chain fragment variable (scFv) antibodies, which consist of a variable heavy chain (VH) and a variable light chain (VL) connected by the linker (Gly4-Ser)3. The linker has been built as a loop structure using the Insight II software. The accuracy of the loop structure has been evaluated using Root Mean Square Deviation (RMSD). The accuracies of the VL and VH tem- plate-based structures are enhanced by using the evaluation methods Verify3D, ERRAT and Ram- chandran plotting, which measure the error in the residues. In the results, 100% of the light-chain resi- dues scored above 0.2, whereas 88.5% of the heavy- chain residues’ scored above 0.15 in the Verify3D evaluation method. Meanwhile, using ERRAT, the alignments of both chains scored more than 70% in space. Additionally, the Ramchandran plot evalua- tion method showed large numbers of residues in the favoured areas in both chains; these findings demon- strated that all of the chosen templates were the best candidates.

DSpace software copyright © 2002-2025 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify